Review





Similar Products

99
Olympus fast scan microscope
Fast Scan Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/VS120+Virtual+Slide+Microscope+Virtual+Slide+Microscopy/pmc12900355-256-12-15
Average 99 stars, based on 1 article reviews
fast scan microscope - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

99
Olympus multispectral fast laser confocal microscope
Multispectral Fast Laser Confocal Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/FV3000+Confocal+Laser+Scanning+Microscope/pm40815895-131-6-12
Average 99 stars, based on 1 article reviews
multispectral fast laser confocal microscope - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

90
Carl Zeiss confocal scanning microscope lsm880 with fast airyscan
Confocal Scanning Microscope Lsm880 With Fast Airyscan, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/browser+image+lsm/pm40664662-86-23-30
Average 90 stars, based on 1 article reviews
confocal scanning microscope lsm880 with fast airyscan - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss lsm880-zeiss confocal laser scanning microscope with fast airyscan
Lsm880 Zeiss Confocal Laser Scanning Microscope With Fast Airyscan, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/browser+image+lsm/pm40586601-81-42-44
Average 90 stars, based on 1 article reviews
lsm880-zeiss confocal laser scanning microscope with fast airyscan - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Miltenyi Biotec ultra-fast laser-scanning multiphoton microscope trimscope ii
Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
Ultra Fast Laser Scanning Multiphoton Microscope Trimscope Ii, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/single+beam+multiphoton+microscope+trimscope/pmc12206270-104-7-13
Average 90 stars, based on 1 article reviews
ultra-fast laser-scanning multiphoton microscope trimscope ii - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Bruker Corporation atomic force microscope bruker dimension fast scan
Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
Atomic Force Microscope Bruker Dimension Fast Scan, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/atomic+force+microscope+dimension+icon/10__1016_slash_j__foodhyd__2025__111671-96-26-32
Average 90 stars, based on 1 article reviews
atomic force microscope bruker dimension fast scan - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Carl Zeiss fluorescence confocal laser scanning microscope zeiss lsm 880 with fast airyscan
Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
Fluorescence Confocal Laser Scanning Microscope Zeiss Lsm 880 With Fast Airyscan, supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/880+confocal+lsm+microscope/10__1021_slash_acselectrochem__5c00053-72-1-5
Average 90 stars, based on 1 article reviews
fluorescence confocal laser scanning microscope zeiss lsm 880 with fast airyscan - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

99
Nikon a1r ultra fast spectral scanning confocal microscope
Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. <t>Multiphoton</t> microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.
A1r Ultra Fast Spectral Scanning Confocal Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/fast+scan+microscope/Objectives/pmc10333845__MSB___19___e11267___s010-580-6-5
Average 99 stars, based on 1 article reviews
a1r ultra fast spectral scanning confocal microscope - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

Image Search Results


Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. Multiphoton microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.

Journal: Journal of Tissue Engineering

Article Title: Comprehensive characterization of cell and tissue responses toward high hydrostatic pressure treatment: Molecular feedback and structural integrity in bone graft processing

doi: 10.1177/20417314251337193

Figure Lengend Snippet: Bone matrix integrity in response to HHP treatment. Human trabecular bone was treated with HHP at 250, 350, and 600 MPa at 10°C for 20 min using 0.9% saline as the pressure-transmitting medium before post-treatment incubation of bone cylinders was conducted at 4°C for 1 h. Multiphoton microscopy images (a–j), showing tissue autofluorescence at 525/50 nm (green; organic matrix components)) and second harmonic generation (SHG) signal at 405/20 nm (blue; fibrillar collagen), using an excitation wavelength of 810 nm. Here, treated bone cylinders (c–h) are compared to untreated bone (a and b) and bone that was autoclaved (i and j) 121°C for 20 min). Scale bar: 100 µm. The collagen I Western blot (k) is based on a native PAGE (1000 ng of protein per band) with the corresponding quantification (l) that was performed using Image Lab quantification of respective band intensities. Mechanical characterization of human trabecular bone cylinders ( n = 9) regarding compressive modulus (m) and strength (n) via a tactile extensometer. Compressive modulus and strength are displayed as means with standard deviation and single values, represented as dots colored according to corresponding bone density values. Statistical analysis of M and N: Kruskal-Wallis test with Dunn’s multiple comparisons test: p > 0.05.

Article Snippet: The multiphoton images were taken utilizing an ultra-fast laser-scanning multiphoton microscope (TriMScope II, LaVision BioTec, Bielefeld, Germany) in combination with a mode-locked femtosecond-pulsed Ti:Sa laser (Chameleon Vision II, Coherent, Santa Clara, CA, USA).

Techniques: Saline, Incubation, Microscopy, Western Blot, Clear Native PAGE, Standard Deviation